Product catalogue 2026, with every datasheetDownload

Low-voltage power cable

N2XY Multi-core power cable, sector conductors

CU / XLPE / PVC

N2XY, layers stripped back
Rated voltage
0.6/1 kV
Reference standard
ISIRI 3569-1IEC 60502-1
Designation
N2XY
Layer structure
CU / XLPE / PVC
  • CUCopper conductor
  • XLPECross-linked polyethylene
Max. conductor temperature
90 °C

کاربرد

Application

For power distribution in open air, underground, indoors, in cable ducts and in power stations, where mechanical damage is not expected.

جدول مشخصات

Datasheet

N2XY 3 × 50

CU / XLPE / PVC

3D model of the cable's layers: N2XY 3 × 50
  • Outer sheath⁦1.8 mm⁩
  • XLPE insulation⁦1 mm⁩
  • Copper conductor

3D reconstruction from this table row. Press the cable to play it again.

N2XY 3 × 50Schematic cross-section, approximate scale
Point at a row to see that size. Select it to rebuild the 3D model too.
Nominal cross-sectionmm²ClassInsulation thicknessmmSheath thicknessmmApprox. overall diametermmMax. conductor resistance at 20 °CΩ/kmApprox. weightkg/km
211.824.20.3871570
21.11.927.70.2682173
21.1231.20.1932917
21.22.134.50.1533655
21.42.338.50.1244489
21.62.442.50.09915593
21.72.647.80.07547304
21.82.852.10.06019048
21 , 0.91.826.70.387 , 0.7271840
21.1 , 0.91.930.40.268 , 0.5242534
21.1 , 1.02.134.20.193 , 0.3873421
21.2 , 1.12.2380.153 , 0.2684357
21.4 , 1.12.341.10.124 , 0.2685170
21.6 , 1.12.548.50.0991 , 0.1936565
21.7 , 1.22.752.80.0754 , 0.1538505
211.927.80.3872076
21.1232.20.2682882
21.12.135.30.1933859
21.22.3400.1534865
21.42.4450.1245959
21.62.648.40.09917431
21.72.855.90.07549721
21.8361.20.060112051

Table source: print page 35 of the 12 November 2023 edition (superseded by the 2026 edition)

This product in the catalogue (PDF)

Aluminium and copperwire and cable,from Kaveh Industrial City

Request a quoteTell us the size and length